Siemens Industrial Ethernet Driver Fact Sheet

Downloads (without a license it runs for 2 hours)

Latest Version Previous versions
Siemens Industrial Ethernet Driver (OPC/iFix version) Version 7.10.56 Version 7.10.55; Version 7.10.54; Version 7.9.51s
Siemens Industrial Ethernet Driver (Citect version) Version 7.10.55 Version 7.10.54(use this for older citect versions)
ISO Install CD images CD V 7.10.55 CD V 7.10.54; CD V 7.10.53; CD V 7.9.51
S7 PLC emulator for testing, training & sales Emmulator

 

Full Printable Manual & FAQ

Trouble Shooting "Failed to Open ISO channel 1" Problem

Revision History

OPC Datahub OPC example

 

Pricing(Per SCADA node)

SIX Driver with online documentation USD $ 700

Driver Name: Siemens Industrial Ethernet for S5, S7 & Simatic TI
Driver Code: SIX
Device Mfr: Siemens AG
Last Update: 08/22/07 10:24:48 PM
Device Supported:
Mfr Device Comments
Siemens AG S5 115U With CP535 or CP143 or CP1430
Siemens AG S5 135U With CP535 or CP143 or CP1430
Siemens AG S5 155 U With CP535 or CP143 or CP1430
Siemens AG S7 300 With CP 343-1 Industrial Ethernet
Siemens AG S7 315-2PN/DP CPU with built in Ethernet
Siemens AG S7 400 With CP 443-1 Industrial Ethernet
Siemens AG S7 200 with CP 243
Siemens AG S7 1200 and S7 1500 built in Ethernet
Siemens AG Logo 8 built in Ethernet
Siemens AG Simatic TI 5x5 With CP1434
Siemens AG WinAC RTX Soft PLC running on windows
Vipa CPU 314NET CPU with built in Ethernet
     

 

Interface Supported:
Interface at SCADA PC Side Comments
Any Ethernet card with an NT NDIS 3.0 driver (All commercially available ethernet cards) Most common cards work well especially Intel chipsets.  We have had some problems with broadcomm.

 

Command Supported:
Device Command Description Uses
All S5 Devices  Read / Write DB & DX Datablocks  Internal Memmory
All S7 Devices  Read / Write  M, DB, I, O All Memmory areas of the PLC - no restrictions
S7-200 Read / Write V,K,X,Y,C,VF,Loops,Alarms All memmory areas are supported
All S7 Devices  Read / Write  M, DB, I, O All Memmory areas of the PLC - no restrictions
Simatic TI Read / Write V,K,X,Y,C,VF,Loops,Alarms All memmory areas are supported

 

Data Type:
Data Type Comments
Float (KG in the S5, IEEE in S7) Supported in the native format of each PLC
Signed (KF in S5)  
Long (DD in S5)   
Ascii read & write ascii data

 

 

Protocol Supported:
Type Protocol  
Multi Drop  Proprietary Siemens protocol on ISO transport layer (supplied with driver) NO Siemens Hardware or software is required at the SCADA PC

 

Comments:
COMMANDS NOT SUPPORTED:
  Flag (MB) Area in S5
   